Technical
Reinforcement to structural screeds
Two construction workers in safety gear examine a tablet on a building site with materials in the background.
© Rouzes

Introduction

This technical document provides additional guidance relating to how the functional and performance requirements in the Technical Manual may be satisfied when selecting reinforcement in structural screeds (also referred to as structural concrete toppings).

Structural screed

A structural screed is a load-bearing structural element. Typically, they are used in conjunction with beam and block floor systems that have non structural infill blocks (lightweight concrete, EPS insulation blocks).

However, structural screeds can also be used as a final layer where insulation is placed on top of a cast in-situ concrete slab construction.

Reinforcement - whether through steel mesh, steel fibres, or macro synthetic fibres - is included to enhance the screed’s structural capacity - improving its strength, durability, and ability to perform effectively within the floor build up.

What are our concerns as a warranty provider?

Specifiers and designers are selecting synthetic fibres that are not of a type or class recognised by the warranty provider as suitable for delivering structural reinforcement within a structural screed

Warranty stance

Structural screeds should be designed and specified by an engineer. Where reinforced, acceptable* materials are:

  • Steel mesh reinforcement, or;
  • Steel fibres to BS EN 14889-1**, or;
  • Class II polypropylene macro fibres to BS EN 14889-2**

Failure to provide the correct reinforcement within a structural screed is considered to compromise the ability of the floor construction and associated materials in meeting with both the functional and performance requirements stipulated by the Technical Manual, notably those relating to structural performance and durability. 

For clarity, specifiers and designers should be aware that the warranty provider does not accept the use of micro-polymer fibres as structural reinforcement in structural screed applications.

Where designing engineers specify a structural screed product which incorporates steel or polypropylene fibres, the fibre product must have an appropriate third-party product conformity certificate from a UKAS accredited organisation.**

The certification must explicitly state:

  • The fibre reinforcement achieves a service life of 60 years, and;
  • can be used as a structural alternative to traditional steel reinforcement for the specific application proposed.

Where a structural screed forms part of a floor system (e.g. beam and block using non-structural infill blocks such as lightweight concrete, EPS insulation blocks), and incorporates steel or polypropylene fibres, the floor system must have an appropriate third-party product conformity certificate from a UKAS accredited organisation. The certification must explicitly state that any fibre inclusion is for the purpose of structural reinforcement and can be used as an alternative to traditional steel reinforcement for the specific application proposed.

In either case, if this statement is omitted or the certificate states that fibres are only for shrinkage control or crack limitation, they cannot be considered an alternative to steel reinforcement and are therefore not acceptable to the warranty provider.

Where micro-polymer fibres are specified in non-structural screeds to assist in controlling shrinkage or cracking, they should be Class I polypropylene micro fibres to BS EN 14889-2 ‘Fibres for concrete — Part 2: Polymer fibres — Definitions, specifications and conformity’.

Developers should ensure that site teams and installing contractors responsible for the execution of work are carefully controlling the dosage and on site mixing requirements in order to achieve the correct specification for the project.

Any quality assurance procedures should be capable of demonstrating this to the satisfaction of the warranty surveyor should this be requested.

*Note: The warranty provider accepts the above list of reinforcement types, the choice of reinforcement type used within a structural screed shall be determined by structural designs for the intended use of the floor structure and any specific loadings associated with its use. In certain situations (e.g. garages), an engineer may limit reinforcement options to steel mesh to accommodate specific loadings.

**Note: All types of fibre reinforcement e.g. steel and polymer fibres must have an appropriate third-party product conformity certificate from a UKAS accredited organisation.

Subscribe to be first to hear about our technical updates

Download a PDF version of this article

Disclaimer

This technical document has been prepared by Premier Guarantee exclusively for the benefit of our registered customers. Its sole purpose is to provide guidance on the utilisation and interpretation of technical requirements pertinent to the warranty cover offered by Premier Guarantee.

Please note that this document is not intended for circulation or use beyond the aforementioned purpose. The information presented herein is for general guidance only and does not constitute professional advice. Registered customers and any other party accessing this document are advised not to rely solely on the information contained within.

Nothing in this document is intended to establish, nor should it be construed as creating, any contractual or legal obligations. In the event that any third party chooses to rely on the information provided, they do so entirely at their own risk. Premier Guarantee explicitly disclaims any duty of care or liability that may arise from the use of or reliance on this document by any third party, howsoever arising.